Cn
Cn
01

Sindie 2622
MWDXRF Sulfur Analyzer

Sindie® 2622 complies with ASTM D2622, D7039 and ISO 20884 methods, enabling complete flexibility in sulfur analysis. With no compromises in detection, performance and reliability, Sindie 2622 is the ideal sulfur analytical solution from ultra low sulfur diesel and gasoline to heavy fuel oil and crudes.

Features

Sindie 2622 

MWDXRF Sulfur Analyzer

  • Using MWD XRF monochromatic wavelength dispersive X-ray fluorescence technology, ultra-low background
  • LOD: 0.15ppm
  • Simple sample preparation and instrument operation process, fast detection
  • Fits on any lab bench, Just plug-in and measure
  • Extremely low maintenance: no conversion gasses, heating elements, columns, or quartz tubing
  • No moving parts in the analyzer
  • Accucell sample cup can be used
  • Option: autosampler
  • Using WD XRF single wavelength dispersive X-ray fluorescence technology, conform to ASTM D2622 and GB/T 11140



Working principle

A monochromatic X-ray beam with a wavelength suitable to excite the K-shell electrons of sulfur is focused onto a test specimen contained in a sample cell. The fluorescent Kα radiation at 0.5373 nm (5.373 Å) emitted by sulfur is collected by a fixed monochromator (analyzer). The intensity (counts per second) of the sulfur X rays is measured using a suitable detector and converted to the concentration of sulfur (mg/kg) in a test specimen using a calibration equation.



Standards

    ASTM D7039-15 Standard Test Method for Sulfur in Gasoline, Diesel Fuel, Jet Fuel, Kerosine,Biodiesel, Biodiesel Blends, and Gasoline-Ethanol Blends by Monochromatic Wavelength Dispersive X-ray Fluorescence Spectrometry
    NB/SH/T 0842-2017 Using monochromatic wavelength dispersive X-ray fluorescence spectrometr to determine Light liquid fuels determination of sulfur content
    ISO 20884-2019 Petroleum products — Determination of sulfur content of automotive fuels — Wavelength-dispersive X-ray fluorescence spectrometry
    ASTM D2622 Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-ray Fluorescence Spectrometry
    GB 11140-2008 Determination of sulfur content in petroleum products, using dispersive X-ray fluorescence spectrometr

Specifications

  • LOD:0.15ppm
  • Dynamic Range: Low Range: 0.15 ppm - 3000 ppm ,High Range: 0.3 wt% - 10 wt%
  • Sample Volume: <10ml
  • Using Mylar film
  • Power only, no combustion and gas consumption
  • With the function of multi calibration curve storage, can measure different samples
  • Measurement: User selectable: 30-900 s

Applications

Petrochemical products such as gasoline, diesel, blending distillate, jet fuel, kerosene, biodiesel, Biodiesel Blended fuel, ethanol gasoline, heavy oil, etc. It is suitable for petrochemical enterprises, refining, quality inspection departments, third-party testing and other industries.